Soilworks products are the industry’s top standard due to our insistence on creating high performance soil stabilization and dust control products that stand up to rigorous testing – both in the lab and in the field. Our commitment to quality and performance has led to our involvement and testing in hundreds of real-world situations. The following library of reports, presentations, specifications, approvals and other similar documents provide you, our customer, the transparency and dependable assurance that is expected from Soilworks.
Independent laboratory testing by Aquatic Consulting & Testing, Inc. confirmed that Durasoil®, a synthetic organic fluid manufactured by Soilworks, contains no detectable levels of extractable pesticides, herbicides, or PCBs under the U.S. EPA’s Toxicity Characteristic Leaching Procedure (TCLP) standards. Using EPA Methods 8081A and 8151A, the analysis verified that Durasoil meets stringent environmental safety criteria, making it suitable for use in sensitive ecological zones, stormwater-regulated areas, and environmentally protected applications where runoff safety is a concern.
For environmental consultants, regulatory compliance officers, and project managers, Soilworks offers:
Durasoil®: Non-toxic, non-hazardous dust suppressant with laboratory-verified TCLP safety compliance
Assurance of no detectable Chlordane, Heptachlor, Lindane, Methoxychlor, or related compounds
Ideal for dust control near wetlands, waterways, schools, and public infrastructure
To meet environmental regulatory standards and ensure safe deployment in ecologically sensitive locations, contact Soilworks for full safety documentation and application support.
Aquatic Consulting & Testing, Inc.
1525 W. University Drive, Suite 106
P.O. Box 1510
Tempe, Arizona 85281
Phone: (480) 921-8044 – FAX: (480) 921-0049 Lic. No. AZ0003
Certificate of Analysis
Tests were conducted during April 2005 using EPA Methods 8081A and 8151A, licensed by Arizona Department of Health Services. The submitted product was analyzed as received by TCLP extraction (EPA Method 1311), with no dilution other than that analytically required.
TCLPExtractable Pesticides, Herbicides, and PCBs
|
Constituent |
Result |
Detection limit |
|
Chlordane |
ND |
0.0500mg/L |
|
2,4,-0 |
ND |
0.1000 mg/L |
|
Endrin |
ND |
0.0500 mQ/L |
|
Heptachlor |
ND |
0.0500 mg/L |
|
Lindane |
ND |
0.0500 mg/L |
|
Methoxychlor |
ND |
0.0500 mg/L |
|
Toxaphene |
ND |
1.00 mQ/L |
|
Silvex |
ND |
0.0100 mg/L |
|
Heptachlor epoxide |
ND |
0.0500 mg/L |
Frederick A. Amalfi, Ph.D.
Laboratory Director
For questions pertaining to these analyses, please contact: Aquatic Consulting & Testing, Inc.
phone: 480-921-8044
e-mail: ramalfi@aquaticconsulting.com