Soilworks products are the industry’s top standard due to our insistence on creating high performance soil stabilization and dust control products that stand up to rigorous testing – both in the lab and in the field. Our commitment to quality and performance has led to our involvement and testing in hundreds of real-world situations. The following library of reports, presentations, specifications, approvals and other similar documents provide you, our customer, the transparency and dependable assurance that is expected from Soilworks.
Laboratory testing by Aquatic Consulting & Testing, Inc. using EPA Methods 1311, 6010B, and 7470A confirmed that Durasoil®, a synthetic organic fluid from Soilworks, exhibits no detectable levels of leachable heavy metals under the Toxicity Characteristic Leaching Procedure (TCLP). All tested metals—including arsenic, cadmium, lead, mercury, and chromium—were reported at concentrations well below regulatory thresholds or not detected at all. This analysis demonstrates that Durasoil meets environmental safety standards for use in applications where potential leaching into soil or water systems is a concern.
For environmental engineers, project managers, and compliance officers, Soilworks provides:
Durasoil®: TCLP-certified dust suppressant with non-detectable leachable metals
Safe for use near water bodies, storm drains, agricultural zones, and sensitive ecosystems
Verified compliance with U.S. EPA and Arizona Department of Health Services testing protocols
To support regulatory approval and environmental stewardship in dust control operations, contact Soilworks for full certification details and Durasoil deployment guidance.
Aquatic Consulting & Testing, Inc.
1525 W. University Drive, Suite 106
P.O. Box 1510
Tempe, Arizona 85281
Phone: (480) 921-8044 – FAX: (480) 921-0049 Lic. No. AZ0003
Certificate of Analysis
Tests were conducted during April and May 2005 using EPA Methods 6010B and 7470A, methods licensed by Arizona Department of Health Services. The submitted product was analyzed as received by TCLP extraction (EPA Method 1311), with no dilution other than that analytically required.
Metals: Leachable {TCLP)
|
Constituent |
Result |
|
Aluminum |
<0.5 mg/L |
|
Antimony |
<0.2 mg/L |
|
Arsenic |
<0.1 mg/L |
|
Barium |
<0.01 mg/L |
|
Beryllium |
<0.01 mg/L |
|
Cadmium |
<0.01 mg/L |
|
Chromium |
<0.05 mg/L |
|
Copper |
<0.02 mg/L |
|
Lead |
<0.2 mg/L |
|
Mercury |
<0.0005 mg/L |
|
Nickel |
<0.02 mg/L |
|
Selenium |
<0.2 mg/L |
|
Silver |
<0.1 mg/L |
|
Thallium |
<0.2 mg/L |
|
Zinc |
<0.03 mg/L |
Frederick A. Amalfi, Ph.D.
Laboratory Director
For questions pertaining to these analyses, please contact: Aquatic Consulting & Testing, Inc.
phone: 480-921-8044