Soilworks products are the industry’s top standard due to our insistence on creating high performance soil stabilization and dust control products that stand up to rigorous testing – both in the lab and in the field. Our commitment to quality and performance has led to our involvement and testing in hundreds of real-world situations. The following library of reports, presentations, specifications, approvals and other similar documents provide you, our customer, the transparency and dependable assurance that is expected from Soilworks.

Durasoil – Boeing BSS7432 Report (TPD2403009)

SMI, Inc.
12219 SW 131 Avenue Phone: (305) 971-7047
Miami, Florida 33186-6401 USA Fax: (305) 971-7048

Attn:

Fabio Neto
Soilworks®, LLC
7150 East Camelback Road Ste 444
Scottsdale, AZ 85151

Product:

DURASOIL (received 19-Jan-2024)

Dilution:
As received

Date:20-Mar-2024
SMI/REF:  2401-724

BOEING SPECIFICATION SUPPORT STANDARD
BSS7432
EVALUATION OF AIRPLANE MAINTENANCE MATERIALS
(Version: Original issue, 28-May-2019 / supersedes Boeing 06-17487)
(Note: Boeing D6-17487 was cancelled and superseded by 8SS7432 on 28-May-2019)

Category: Exterior and General Cleaners and Liquid Waxes, Polishes and Polishing Compounds

Sandwich Corrosion Test Conforms
Acrylic Crazing Test Conforms
Paint Softening Test Conforms
Hydrogen Embrittlement Test Conforms

 

Respectfully Submitted,

Jeff Nottebaum, SMI Inc.

Director

Rae-anne Nottebaum, SMI Inc.
Chemist

 

SCIENTIFIC MATERIAL INTERNATIONAL
w w w. s m i i n c . c o m

 

Page 1 of 4

Client: Soilworks®, LLC
Product: DURASOIL
Dilution: As received

BSS7432 (Exterior &.General)

Date: 20-Mar-2024

SMI/REF: 2401-724

Page 2 of 4

Sandwich Corrosion Test: Specimen preparation, testing, and interpretation must be in accordance with ASTM Fl11O using the following materials and with the following exceptions:
a.   Reagents and materials exception:
(1).  Clad 7b75-T6 aluminum alloy in accordance with AMS-QQ-A•250/13 {AMS 4049 or AMS-QQ-A-250/13 optional) (2024-T3 Alclad specimens are neither required nor optional.)
(2) Bare 7075-T6 aluminum alioy in accordance with AMS-QQ-A-250/12 (AMS
4045 or AMS-Q,.A-250/12 optional) anodized in accordance with BAG 5019 or MIL-A-8625, Type L •
(3) Anodize must be sealed. (2024-T3 nonclad specimens are neither required nor optional). •
(4) Distilled or deionized water may be used in place of ASTM F1193, Type IV reagent grade water for control specimens.
(5) The filter paper may be Whatman No. 5 or equivalent in place of Whatman GFA glass fiber paper.
b. Procedure exceptions: .
(1) The filter paper strips must be 1 by 3 inches and must be placed in the center of the sandwiched specimens.
(2) Each sandwich specimen must be held together with waterproof tape, with no more than 1 piece of tape (maximum width 0.75 inch) on each of two opposite edges.
c.    Interpretation of result exceptions:
(1) Leaching or lightening of the chromate seale:d anodize coating must not be cause for rejection.
(2) Deposits or residues from the material being tested that are not products of corrosion of the test panel surface must not be cause for rejection.
(3) Special procedure for evaluation of fire extinguishing foams and liquids. Panels with very light darkening or staining, which have no obvious metal attack or pitting, may be swabbed (cotton4ipped swabs or. cotton gauze) with a 0.26 mole/Iiter sulfuric acid solution and re-examined. If the coloration is substantially removed and there is no evidence of metal attack or pitting, the condition must not be cause for rejection. (The0.Z6·mole/liter sulfuric acid solution can be prepared by adding 1.5 cc of concentrated sulfuric acid (SG = 1.84) to 100 cc of distilled or deionized water.
(4) Panels must have a rating of 1 (no more than 5 percent of the surface area must be corroded) or better in accordance with ASTM F 1110. The preferred method of determining the corroded area is by using image analysis. Other means approved by the purchaser may be substituted.
(5) Any corrosion in excess of that shown by the control group must be cause for rejection.

Client: Soilworks®, LLC
Product: DURASOIL
Dilution: As received BSS7432 (Exterior & General)
SandwichCorrosion Test: continued

Date:20-Mar 2024

SMI/REF:2401-724
Page 3 of 4

Bare 7075-T6 (AMS4045)
Anodized per BAO 5019.
{Type 3·chromate.se.al) Clad 7075-T6 Aluminum (AMS 4049)
PRODUCT 1 1
Control 1 1

Result Conforms

Acrylic Crazing Test:.
The material being tested must not craze, crack, or etch acrylic test specimens – when tested in accordance with ASTM F 484 using Type C (stretched acrylic plastic in accordance with MIL-P-25690) stressed to an outer fiber stress of 4500 psi.
PRODUCT: No crazing, cracking, or etching

Result Conforms

Paint Softening Test Procedure:
a. Testing must be in accordance with ASTM F502 using the following coating systems.
(1) BMS 10-79, Type II primer applied in accordance with BAC5882 plus BMS 10-60, Type II enamel in accordance with BAC5845.
(2) BMS t0 79, Type Ill primer applied inaccqrdance with BAC5882; plus BMS.10-100 coating in accordancewith BAC5797.
b. Three specimens conforming to Section 7.7.a.(1) and three specimens conforming to Section 7.7 -(2) must l:ie used for each test condition. •
c. The material being tested must not produce a decrease in film hardness greater than two pencils, or any discoloration or staining.
NOTE: Slight darkening of the.BMS 10-100 surface is acceptable.
As received: Paint system 1: < 2 pencil hardness change after 24 hour post-exposure dry time.
No staining/discoloration
Paint system 2: <2 pencil hardness change after 24 hour post exposure dry time.
No staining/discoloration

Result Conforms

Client: Soilworks®, LLC Product: DURASOIL Dilution: As received BSS7432 (Exterior& General)

Date:20-Mar-2024

SMI/REF:2401-724

Page4 of 4

Hydrogen· Embrittlement Test:
Hydrogen Embrittlement testing must be in accordance with ASTM F 519 using cadmium plated Type 1a.2, Type 1c, or Type 2a specimens. All requirements of ASTM F519 for specimens, preparation, testing and reporting must apply. Type 1a.2 specimens must meet the requirements of D6-4307. • .
Specimens: Type 1c, cadmium plated perMIL-STD-810.
(45¾ load, 150 hours, notched immersed for the duration, room temp.)

As received:

#1:  No·failure occurred within 150 hours.

#2: No failure occurred within 150 hours.

#3: No failure occurred within 150 l1ours.

#4:  No failure occurred within 150 hours.

Result Conforms

 